HARMONY RESORTS - POOL - 2024-06-03

Pass

Facility Information

Site Address
5279 County Road 17
Alfred, Ontario, K0B 1A0
Community
Alfred Station
Facility Type
Outdoor

Inspection Detail

Date
2024-06-03
Inspection Type
Required

Inspection Results

Result Compliance
At least 14 days before a public pool or public spa is put into use after construction or alteration, the owner or the owner’s agent shall notify, in writing, the medical officer of health or the public health inspector.
  • Provide notification for re-opening after closure exceeding four weeks.
Not In Compliance
Deck, dressing rooms, washrooms, and showers maintained appropriately.
  • Keep surfaces clean, free from slipperiness and disinfected.
Not In Compliance
Facility completes daily records as required.
  • Record the estimated number of bather uses during the operating day.
  • Record the reading of the make-up water meter for pools and, if applicable, for spas, as of the end of the day.
Not In Compliance
Facility completes weekly or monthly tests as required.
  • Determine the concentration of cyanuric acid not less than once every week, where cyanurate stabilization is maintained.
  • Test-buttons associated with the ground current leakage detecting and de-energizing devices are activated daily, and tested either monthly or in accordance with manufacturer's directions, whichever is more frequent.
Facility maintains total alkalinity level as required.
  • Maintain total alkalinity in the range of 80 ppm to 120 ppm.
Not In Compliance
Pool basin meets requirements of regulation.
  • Provide a black disc 150 millimetres in diameter on a white background is affixed to the bottom of the pool at its deepest point.
Corrected During Inspection
Written emergency and operational procedures and instructions are available.
  • Ensure that written emergency and operational procedures and instructions are available at the pool to be implemented in the event of an emergency, accident or injury in the pool.
Not In Compliance
Emergency telephone meets requirements for facility type.
  • Class B Pool - provide a telephone for emergency use accessible, and no farther than 30 metres from the pool.
Not In Compliance

Actions Taken

  • Inspection Report Provided
  • Satisfactory - Follow-up action required
Click here to return to the previous page.